Bromination Fresh Fill
Make sure that all the equipment is in place and working properly. It is necessary to use an automatic brominator. Brominating Tablets cannot be used in skimmers, floaters, or automatic chlorinators. Check the sizing chart on the brominator to make sure it is adequate for your pool volume.
Perform a complete water analysis and follow Pool Man recommendations for balancing the water and shocking to establish a sanitiser residual.
Fill the brominator according to manufacturer instructions and set the brominator output to high to begin establishing a total bromine reading. To test manually for the total bromine residual, use the same DPD #1 tablet as for testing the free chlorine residual.
Test the total bromine each day for the first two weeks and shock as needed. It may be necessary to shock periodically with 1 bag of Lite per 50,000 litres or 150 grams of Burn Out 35 per 10,000 litres while the brominator works to establish a residual.
When the total bromine residual is held consistently, adjust the feeder to the appropriate level. Maintain 2.0 - 4.0 ppm total bromine residual for residential pools and 4.0 - 6.0 ppm for commercial pools.
Posted By Red Baron on Friday 29th January 2010 @ 14:10:20
Updated : Wednesday 22nd February 2012 @ 10:15:05 | Words : 196 | Views : 195 | Comments : 0
Blog Categories
Bioguard Pool Product Information
Pool and Spa Industry Fact Sheets
Pool Opening and Closing
Pool Operation and Maintenance
Pool Troubleshooting
Pool Water Balance
Spa Operation and Maintenance
Spa Product Information
Spa Troubleshooting
Spa Water Balance
Ozonators
Ozonators Ozone is often used in spas and pools to help reduce contaminants. Used by itself, it is . . .
Posted By Red Baron on Friday 29th January 2010
Words : 329 | Views : 178 | Comments : 0
Ionisers
Ionisers Copper and Silver are sometimes used as sanitisers in swimming pools. In a process called . . .
Posted By Red Baron on Friday 29th January 2010
Words : 424 | Views : 435 | Comments : 0
Automatic Chlorine and Acid Dispensers
Automatic Chlorinators Chemigem D10 (DM52) WITH VALVES. Chlorine and pH controller suitable for mos . . .
Posted By Red Baron on Friday 29th January 2010
Words : 252 | Views : 199 | Comments : 0
Blogger : red-baron
. . .
Registered Since Tuesday 28th February 2012
Topics : 103 | Comments : 0